MOREL

Case Study

INSTALLATION

MOREL10W (Warm White)
Lines: 5
MOREL lamps per line: 46
Total MOREL lamps: 230

CHICKEN HOUSE DATA

HOUSE LENGTH
HOUSE WIDTH
HOUSE SIDE CURTAINS HEIGHT
HOUSE LIGHTS HEIGHT
WALL COLOR
FLOOR COLOR
CEILING COLOR
REFERENCE PANEL HEIGHT (FLOOR)
REFERENCE PANEL DISTANCE (WALL)

165 m.
15 m.
2.5 m.
.3/1/1.5/2 m.
White
Brown
White
0.1 m. from oor
0.1 m. from wall

SPECIFICATIONS

BRAND
MODEL
TECHNOLOGY
POWER
EFFICIENCY RATE
EFFICACY
CLASSIFICATION
CIE FLUX CODES
UGR (4H 8H)
ILLUMINANCE FLUX
CCT
CRI
DIMENSIONS (mm.)

AMTEK
MOREL
LED
10 W
100%
76 lm./W
B21 | 75.0% | 25.0%
25 51 77 75 100
59.9 / 65.1
760 lm. delivered
2800 Kelvin
> 85 Ra.
ø95 × 205

WIRING & POWER SUPPLY

FLOOR PLAN

ILLUMINANCE

Illuminance refers to the total luminous flux incident on a given surface, per unit area (lx.). Since MOREL luminaires are placed at different levels within the chicken house, the varying illuminance measurements at each level are shown below.

Room height: 3.50 m.
Height of ref. plane: 0.30 m.
Height of luminaire plane: 2.30 m.
As shown on the illuminance color bar, the green area perceives between 30-50 lx.

RESULTS AT HEIGHT REFERENCE OF 0.30 m.

AVERAGE ILLUMINANCE (Em.)
MINIMUM ILLUMINANCE (Emin.)
MAXIMUM ILLUMINANCE (Emax.)
Uo UNIFORMITY (Emin./Em.)
Ud DIVERSITY (Emin./Emax.)
UGR (12H 8H)

34.8 lx.
25.8 lx.
47.9 lx.
1:1.35 (0.74)
1:1.86 (0.54)
≤ 66.4

ILLUMINANCE (cont’d)

Room height: 3.50 m.
Height of ref. plane: 1.00 m.
Height of luminaire plane: 2.30 m.
As shown on the illuminance color bar, the orange area perceives between 30-50 lx. and the green area between 50-75 lx.

RESULTS AT HEIGHT REFERENCE OF 1.00 m.

AVERAGE ILLUMINANCE (Em.)
MINIMUM ILLUMINANCE (Emin.)
MAXIMUM ILLUMINANCE (Emax.)
Uo UNIFORMITY (Emin./Em.)
Ud DIVERSITY (Emin./Emax.)
UGR (12H 8H)

45.8 lx.
28.1 lx.
69.5 lx.
1:1.63 (0.61)
0.40
≤ 66.4

ILLUMINANCE (cont’d)

Room height: 3.50 m.
Height of ref. plane: 1.50 m.
Height of luminaire plane: 2.30 m.
As shown on the illuminance color bar, the illuminance at a ref. plane height of 1.50 m. varies from 0-100+ lx., depending on the location of the measurement taken.

RESULTS AT HEIGHT REFERENCE OF 1.50 m.

AVERAGE ILLUMINANCE (Em.)
MINIMUM ILLUMINANCE (Emin.)
MAXIMUM ILLUMINANCE (Emax.)
Uo UNIFORMITY (Emin./Em.)
Ud DIVERSITY (Emin./Emax.)
UGR (12H 8H)

57.6 lx.
24 lx.
148 lx.
1:2.38 (0.42)
0.16
≤ 66.4

ILLUMINANCE (cont’d)

Room height: 3.50 m.
Height of ref. plane: 2.00 m.
Height of luminaire plane: 2.30 m.
As shown on the illuminance color bar, the illuminance at a ref. plane height of 2.00 m. varies from 0-200+ lx., depending on the location of the measurement taken.

RESULTS AT HEIGHT REFERENCE OF 2.00 m.

AVERAGE ILLUMINANCE (Em.)
MINIMUM ILLUMINANCE (Emin.)
MAXIMUM ILLUMINANCE (Emax.)
Uo UNIFORMITY (Emin./Em.)
Ud DIVERSITY (Emin./Emax.)
UGR (12H 8H)

117 lx.
21 lx.
1350 lx.
1:5.56 (0.18)
0.02
≤ 66.4

3D LUMINANCE

3D Luminance refers to the amount of light that is reflected by a given surface or object.

3D PSEUDO COLORS ILLUMINANCE