PIKON
Case Study
INSTALLATION
PIKON 9W (Warm White)
Lines: 4
PIKON lamps per line: 42
Total PIKON lamps: 168
CHICKEN HOUSE DATA
HOUSE LENGTH
HOUSE WIDTH
HOUSE SIDE CURTAINS HEIGHT
HOUSE LIGHTS HEIGHT
WALL COLOR
FLOOR COLOR
CEILING COLOR
REFERENCE PANEL HEIGHT (FLOOR)
REFERENCE PANEL DISTANCE (WALL)
165 m.
15 m.
2.5 m.
2.3 m.
White
Brown
White
0.1 m. from floor
0.1 m. from wall
SPECIFICATIONS
BRAND
MODEL
TECHNOLOGY
POWER
EFFICIENCY RATE
EFFICACY
CLASSIFICATION
CIE FLUX CODES
UGR (4H 8H)
ILLUMINANCE
FLUX
CCT
CRI
DIMENSIONS (mm.)
AMTEK
PIKON
LED
9 W
100%
111.11 lm./W
A31 | 92.7% | 7.3%
39 68 87 93 100
61.9 / 61.6
1000 lm. delivered
3000 Kelvin
> 85 Ra.
ø151 × 242
PIKON
LED
9 W
100%
111.11 lm./W
A31 | 92.7% | 7.3%
39 68 87 93 100
61.9 / 61.6
1000 lm. delivered
3000 Kelvin
> 85 Ra.
ø151 × 242

WIRING & POWER SUPPLY

FLOOR PLAN

ILLUMINANCE
Illuminance refers to the total luminous flux incident on a given surface, per unit area.

As shown on the illuminance color bar, the orange area perceives between 30-50 lx. and
the green area between 50-75 lx.
RESULTS AT HEIGHT REFERENCE OF 0.10 m.
AVERAGE ILLUMINANCE (Em.)
MINIMUM ILLUMINANCE (Emin.)
MAXIMUM ILLUMINANCE (Emax.)
Uo UNIFORMITY (Emin./Em.)
Ud DIVERSITY (Emin./Emax.)
UGR (12H 8H)
61.3 lx.
42.7 lx.
76.32 lx.
1:1.43 (0.70)
1:1.78 (0.56)
≤ 63.4
3D LUMINANCE
3D Luminance refers to the amount of light that is reflected by a given surface or object.

3D PSEUDO COLORS ILLUMINANCE
3D Luminance refers to the amount of light that is reflected by a given surface or object.